Yide Sensors Inc.
NEA Loadcell (NEA)
Short Description:
Aluminum-alloy IP65 single point load cell
Colourless anodized
Suitable for single and double load cells structured platform scales
Maximum platform size: 600 x 600 mm
A 1000 Ohm type available (R1) but is excluded from OIML
Manufacturer: Yide Sensors Inc.
Origin: Made in Australia
Available Capacity:
Capacity Accuracy Full Article Description 50kg C3 NEA-50kg 100kg C3 NEA-100kg 150kg C3/C4 NEA-150kg 200kg C3/C4 NEA-200kg 250kg C3/C4 NEA-250kg 300kg C3/C4 NEA-300kg 500kg C3/C4 NEA-500kg
Technical Specifications of NEA
Accuracy Class OIML R60 C3, OIML R60 C4 Output Sensitivity ( FS ) mV/V 2.0 ± 0.2 Maximum Capacity ( Emax ) kg 50, 100, 150, 200, 250, 300, 500, 600; 150, 200, 250, 300, 500, 600 Max. Number of Load Cell Intervals nLC 3000, 4000 Ratio of min. LC Verification Interval Y = Emax / Vmin 10000, 15000 Combined Error %FS ≤± 0.02 Creep Error (30 minutes) %FS ≤± 0.02 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.0230; ≤± 0.0175 Minimum dead load Of Emax 0% Safe overload Of Emax 150 % Ultimate Overload Of Emax 300 % Zero balance Of FS ± 2.0 % Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 750±6 Output Resistance Ω 700±3 Insulation Resistance MΩ 5000 (at 50VDC) Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Element Material Aluminum Ingress Protection (acc. to EN 60529) IP65 Recommended Torque on Fixation Bolts Nm M8:25
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6mm
Cable length: 3m
Shield connected to element
Cable jacket in PVC
Wiring Instruction:
Input(Positive) - Red
Output(Positive) - Green
Output(Negative) - Blue
Input(Negative) - Yellow
Used in Single Point Platform, Automated servo belt system, PLC Application, Conveyer system, small floor scale platform
UH62 Loadcell (UH62)
Short Description:
Nickel plated alloy steel IP66 single point load cell
Bending beam
Suitable for belt, platform and other electronic weighing devices
Maximum platform size:
1. for 50kg-200kg: 400 x 400 mm
2. for 250kg-500kg: 600 x 800 mm
3. for 750kg-2t: 1200 x 1200 mm
Manufacturer: Yide Sensors Inc.
Origin: Made in Australia
Available Models:
Capacity Accuracy Full Article Description 100kg C3 UH62-C3-100kg-3B6 150kg C3 UH62-C3-150kg-3B6 200kg C3 UH62-C3-200kg-3B6 250kg C3 UH62-C3-250kg-3B6 500kg C3 UH62-C3-500kg-3B6 750kg C3 UH62-C3-750kg-3B6 1000kg C3 UH62-C3-1000kg-3B6 2000kg C3 UH62-C3-2000kg-3B6
Technical Specifications of UH62
Accuracy Class C3 Output Sensitivity ( FS ) mV/V 2.0 ± 0.2 Maximum Capacity ( Emax ) Kg 100, 150, 200, 250, 500, 750, 1000, 2000 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / Vmin 7500 Combined Error %FS ≤± 0.020 Minimum dead load Of Emax 0% Safe overload Of Emax 150 % Ultimate overload300 % Of Emax 300 % Zero balance Of FS < ± 1.0 % Excitation, recommended voltage V 5 ~ 12 Excitation maximum V 18 Input Resistance Ω 406 ± 3 Output Resistance Ω 350 ± 3 Insulation Resistance MΩ ≥5000 (at 50VDC) Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Element Material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP66 Recommended Torque on Fixation Bolts Nm M12:75; M16:200 ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6.2mm
Standard cable length: 3m
Shield not connected to element
Wiring Instruction:
Input (Positive) - White
Sense (Positive) - Brown
Output (Positive) - Red
Output (Negative) - Black
Sense (Negative) - Green
Input (Negative) - Yellow
Dimension Wise Capacity:
Dimension Capacity B B1 H H1 H2 L L1 L2 M 50-200kg 44 24 75 50 30 156 112 14 M12 250-500kg 60 36 95 70 30 146 110 11 M12 750kg-2000kg 76 46 125 95 65 176 110 24 M16
Single Point Platform, Automated servo belt system, PLC Application
- 1