Latest Products

BM11 Load Cell

Used in Hopper Scale, Automated servo belt system, PLC Application.
৳0.00  Inc Tax
Qty:
Short Description:
Stainless steel IP68 single ended bending beam
Hermetically sealed
Suitable for pallet, platform and small hopper scales
High accuracy
Current calibrated (SC-option)
Manufacturer:
Zemic Europe
Origin:
B.V Netherland
Available Models:
Capacity Accuracy Full Article Description
5kg C3 Excluded from OIML BM11-C3-5kg-3B-SC
10kg C3/C4 BM11-C3/C4-10kg-3B-SC
20kg C3/C4 BM11-C3/C4-20kg-3B-SC
30kg C3/C4 BM11-C3/C4-30kg-3B-SC
50kg C3/C4 BM11-C3/C4-50kg-3B-SC
100kg C3/C4 BM11-C3/C4-100kg-3B-SC
200kg C3/C4 BM11-C3/C4-200kg-3B-SC
250kg C3/C4 BM11-C3/C4-250kg-3B-SC
350kg C3/C4 BM11-C3/C4-350kg-3B-SC
500kg C3/C4 BM11-C3/C4-500kg-3B-SC
Technical Specifications of BM11
Accuracy Class C3; OIML R60 C3; OIML R60 C4
Output Sensitivity (FS) mV/V 2.0 ± 0.2
Maximum Capacity (Emax) kg 5,10, 20, 30, 50, 100, 200, 250, 350, 500
Max. Number of Load Cell Intervals nLC 3000; 4000
Ratio of min. LC Verification Interval Y = Emax / Vmin 10000; 15000
Combined Error %FS ≤± 0.020; ≤± 0.0174
Creep Error (30 minutes) %FS ≤± 0.016; ≤± 0.012
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.015; ≤± 0.010
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.011; ≤± 0.009
Zero balance %FS ≤± 1.0
Safe overload %FS 150
Ultimate Overload %FS 300
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 460 ± 50
Output Resistance Ω 350 ± 3.5
Insulation Resistance ≥5000
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Load Cell Weight kg ~0.50
Element Material Stainless Steel
Ingress Protection (acc. to EN 60529) IP68
Recommended Torque on Fixation Bolts Nm M8: 25; M10: 50
ATEX Classification (optional) II 1G Ex ia IIC T4 Ga; II 1D Ex ia IIIC T 200 135°C Da; II 3G Ex ic IIC T4 Gc
Wiring:
Cable type: Shielded, 6 and 4 conductor cable , conductor AWG 24
Cable diameter: Ø 5.0mm
Cable length: 4 conductor: 3m, 6 conductor: 6m
Cable jacket: Polyurethane
Shield not connected to element
Wiring Instruction:
For 4 Wire Loadcell:
Input (Positive) - Green
Output (Negative) - Red
Input (Negative) - Black
Output (Positive) - White
For 6 Wire Loadcell:
Input (Positive) - Green
Sense (Positive) - Yellow
Output (Negative) - Red
Input (Negative) - Black
Sense (Negative) - Blue
Output (Positive) - White
  • Availability: Pre-Order
  • Model: BM11
  • Brand: Zemic Europe

Write Review

Note: Do not use HTML in the text.