Nickel plated alloy steel IP67 shear beam load cell
Adhesive sealed
Suitable for platform weighing, bed weighing, etc.
High accuracy
High reliability
Current calibrated (SC-option)
Manufacturer: Zemic Europe
Origin: B.V Netherland
Available Models:
Capacity Accuracy Full Article Description 100kg C3/C4/C5 H8C-C3/C4/C5-100kg-4B(-SC-W6) 250kg C3/C4/C5 H8C-C3/C4/C5-250kg-4B(-SC-W6) 500kg C3/C4/C5 H8C-C3/C4/C5-500kg-4B(-SC-W6) 750kg C3/C4/C5 H8C-C3/C4/C5-750kg-4B(-SC-W6) 1ton C3/C4/C5 H8C-C3/C4/C5-1.0t-4B(-SC-W6) 1.5ton C3/C4/C5 H8C-C3/C4/C5-1.5t-4B(-SC-W6) 2ton C3/C4/C5 H8C-C3/C4/C5-2.0t-4B(-SC-W6) 2.5ton C3/C4/C5 H8C-C3/C4/C5-2.5t-6B(-SC-W6) 3ton C3/C4/C5 H8C-C3/C4/C5-3.0t-6B(-SC-W6) 5ton C3/C4/C5 H8C-C3/C4/C5-5.0t-6B(-SC-W6) 10ton C3/C4/C5 H8C-C3/C4/C5-10t-6B(-SC-W6)
Technical Specifications of H8C
Accuracy Class OIML R60 C3, OIML R60 C4, OIML R60 C5 Output Sensitivity ( FS ) mV/V 3.0 ± 0.003 Maximum Capacity ( Emax ) ton 0.1, 0.25, 0.5, 075, 1, 1.5, 2, 2.5, 3, 5, 10, 01, 0.25, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 5, 10 Max. Number of Load Cell Intervals nLC 3000, 4000, 5000 Ratio of min. LC Verification Interval Y = Emax / Vmin 10000, 15000, 20000, 18000 Combined Error %FS ≤± 0.023; ≤± 0.0175; ≤± 0.014 Creep Error (30 minutes) %FS ≤± 0.016; ≤± 0.012; ≤± 0.010 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.015; ≤± 0.010; ≤± 0.007 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.011; ≤± 0.009; ≤± 0.008 Zero balance %FS ≤± 1.0 Safe overload %FS 150 Ultimate Overload %FS 300 Maximum Deflection mm 0.1t – 0.2t: 0.3 0.5t – 5t: ~ 1.2 10t: 0.8 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 350 ± 3.5 Output Resistance Ω 350 ± 3.5 Insulation Resistance MΩ ≥5000 Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 80 Load Cell Weight kg 0.1t – 2.0t: ~ 0.9; 2.5t – 5t: ~ 1.7; 10t: ~ 3.6 Element Material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP67 Recommended Torque on Fixation Bolts Nm M12: 100 M18:200 M24:700 ATEX Classification (optional) II 1G Ex ia IIC T4 Ga II 1D Ex ia IIIC T 200 135°C Da II 3G Ex ic IIC T4 Gc
Wiring:
Cable type: Shielded, 4 or 6 conductor cable, conductor AWG 22
Cable diameter: Ø 5.0mm
Cable length: 4m for 100kg – 2t; 6m for higher capacities
Shield not connected to element
Wiring Instruction:
For 4 Wire Loadcell:
Input(Positive) - Red
Output(Negative) - White
Input (Negative) - Black
Output(Positive) - GreenFor 6 wire Loadcell:
Input(Positive) - Red
Sense (Positive) - Blue
Output(Negative) - White
Sense (Negative) - Yellow
Input (Negative) - Black
Output(Positive) - Green
Ordering Info:
Example: H8C – C3 – 1.0t – 4 – – BX – SC – XX
H8C Load Cell model C3 Maximum load cell divisions 1.0t Nominal capacity (Emax) for Metric in t (ton) 4 Length of the cable in meters Thread option. No mark is Metric thread and “Y” is Imperial thread BX Cable option. No mark is 4 conductor cable and with a “6” a 6 conductor cable SC Option SC (standard current) XX Option XX. No mark is standard version, W4 is through loading hole, W6 is “T” end loading hole
Write Review
-